Applied Voltage Rated Voltage
 110115120208220230240277380415440460480550
110100%91%84%28%25%23%21%16%8.4%7%6.2%5.7%5.2%4%
115109%100%92%31%27%25%23%17%9.0%7.6%6.7%6.2%5.7%4.3%
120119%109%100%33%30%27%25%19%10%8.4%7.4%6.8%6.3%4.8%
208   100%89%82%75%56%30%25%22%20%19%14%
220   112%100%91%84%63%34%28%25%23%21%16%
230    109%100%92%69%37%31%27%25%23%17%
240    119%109%100%75%40%33%30%27%25%19%
277       100%53%45%40%36%33%25%
380        100%84%74%68%63%47%
415        119%100%89%81%75%57%
440         112%100%91%84%64%
460          109%100%92%70%
480 Actual Wattage = Rated Wattage x (Applied Voltage)²
(Rated Voltage)²
 119%109%100%76%
550     100%